Fire protection project

Comprehensive solutions for the safety of buildings and structures

Why is a fire protection project necessary?

✔ Mandatory for facility commissioning

✔ Guaranteed compliance with the standards of the Ministry of Emergency Situations of the Republic of Uzbekistan

✔ Optimization of material and labor costs

✔ Improving the fire resistance of structures

Project development stages:

  1. Documentation review – study of the facility's structural features
  2. Site survey – assessment of the current structural condition, primer layer integrity and thickness, and fire resistance
  3. Material selection – identifying optimal fire protection solutions and verifying compatibility with existing coatings
  4. Feasibility study – calculation of effective and economical solutions
  5. Documentation preparation – process maps, certificates, and specifications
  6. Regulatory approval – obtaining project approval from regulatory bodies

Our strengths:

✅ Official approval for fire protection design

✅ Compliance with all Urban Development Norms and Regulations (SHNK), ISO, KMK, SNiP, and GOST standards

✅ Accurate calculation of protected volumes and material consumption

✅ Full support for fire protection design approval with the Ministry of Emergency Situations of the Republic of Uzbekistan

✅ Guaranteed passage of inspections by the State Architectural and Construction Supervision (GASN)

What do we protect?

  • Load-bearing metal structures
  • Enclosing structures
  • Evacuation routes
  • Utilities

Design Cost

Our pricing is determined individually after:
• A specialist's on-site visit
• Evaluation of the project scope
• Analysis of design specifics

Note! Having a fire protection project:
  • Significantly reduces the time required to commission a facility
  • Eliminates problems during inspections
  • Ensures the safety of people and property
Aksiya: Yong‘indan himoya qilish loyihasi materiallar va montaj bilan birga buyurtma qilinganda – loyihani ishlab chiqish va kelishish bepul!

What we need from you to start

  • Steel structure drawings (design or shop drawings) with element profiles and sections.
  • Required fire resistance ratings of the structures — from the design or special technical conditions.
  • Primer details if the steel is already painted: product and film thickness.
  • Service conditions: inside or outside the building, humidity, aggressive environment.

If some documents are missing, we will help restore the input data from a site survey.

Why coating thickness differs from beam to beam

A thin section heats up faster in a fire than a massive one, so it needs a thicker fire protection coat. In the design we calculate the thickness for each section type separately — so material is not wasted on massive members and not skimped where it is needed.

The thickness schedule is the key design document

The schedule gives the required coating thickness for every beam, column and brace. The crew applies the fire protection to it, and at acceptance every member is checked against it — no arguments about whether the coat is thick enough.

Over 20 years of fire protection experience, ISO 9001 and ISO 45001 certified. We work across Uzbekistan.

See also: Fire protection of steel structures · Repair of fire protection coatings

Contact

    English
    Telegram
    DQS work geography across Uzbekistan